Call: 800-825-0717

Corrosion Resistant Metals
for Corrosive Environments

Type "S" Form Deck

Type S Deck is used when a non-composite slab is required and the clear span is short.

Type

 

Section Properties (Fy=80 ksi)
Gage Design Thickness Weight (psf)GIV Ip(1n4) Sp(In3) Sn(In3) Download
28 0.0149 0.85 0.012 0.035 0.035
26 0.0179 1.02 0.014 0.045 0.045
24 0.0238 1.30 0.019 0.060 0.060
22 0.0295 1.55 0.023 0.074 0.074
Section properties calculated in accordance with AISI specifications    

 

Span Condition   Gage Design Criteria Uniform Total Load 'n Pounds Per Sauare Foot (Dead and Live)
2'-0" 2'-6" 3'-0" 3'-6" 4'-0" 4'-6" 5'-0" 5'-6" 6'-0"
          One            28 36000 211 135 94 69 52 41 33    
L240 94 48 28            
L180 126 64 37 23          
26 36000 267 171 118 87 66 52 42    
L240 114 58 33 21          
L180 152 77 45 28          
24 36000  * 231 160 118 90 71 57 47 40
L240 151 77 45 28          
L180 202 103 60 37 25        
22 36000 * 284 197 -145.. 111' 87 71 58 49
L240 188 96 55 35 23        
L180 251 128 74 46 31     1'  

Two 28 36000 221   98 72 55 43 35    
L240 228 117 67 42 28 20 ~\    
L180 * 156 90 56 38 26      
26 36000 270 173 120 88 67 53      
L240 275 140 81 51 34 24      
L0180   187 108 68 45 32      
24 36000   231 160 118 90 71 57 47 40
L240   187 108 68 45 32 23    
L180   249 144 91 61 42 31    
22 36000   284 197 145 111 87 71 58 49
L240   232 134 84 56 39 29 21  
L180     179 113 75 53 38 29  

Three or More 28 36000 273 177 123 90 69 54 44    
L240 179 92 53 33 22        
L180 239 122 71 44 29        
26 36000 * 216 150 110 84 66 54    
L240 216 110 64 40 27        
L180 288 147 85 53 36        
24 36000 * 289 200 147 112 89 72 59 50
L240 287 147 85 53 35 25      
L180 * 196 113 71 47 33      
22 36000   * 247 181 139 109 89 73 61
L240   182 105 66 44 31 22    
L180   243 141 88 59 41 30    

James River Steel, Inc.
P.O. Box 11498 Richmond, VA 23230

1-800-825-0717 Toll Free
E-mail: info@jamesriversteel.com

1-804-285-0717 in Va
1-804-285-0780 Fax