LOAD CHART
SUGGESTED UNIFORM ROOF LOAD IN POUNDS PER SQUARE FOOT
GAGE SPAN 6'-0" 6'-6" 7'-0" 7'-6" 8'-0" 8'-6" 9'-0" 9'-6" 10'-0" 10'-6" 11'-0" 11'-6" 12'-0" 12'-6" Download
18 stl. 1
3
122
156
109
139
94
120
82
104
72
92
64
81
57
72
51
65
46
59
42
53
39
49
35
44
32
41
30
38
20 stl. 1
3
84
105
75
97
64
83
56
73
49
64
44
57
39
50
35
45
32
41
29
37
26
34
24
31
22
28
20
26
22 stl. 1
3
67
82
58
75
50
65
44
56
39
49
34
44
30
39
27
35
25
32
22
29
21
27
19
24
17
22
16
20
24 stl. 1
3
49
63
43
55
37
47
32
41
29
36
25
32
23
29
20
26
18
23
17
21
14
18
13
17
13
16
12
15
0.032 alum. 1
3
Available on Inquiry
0.040 alum. 1
3
Available on Inquiry
Notes:
1. Loads shown based on stress governing per AISC specs.

Request a Quote

Take the first steps to solving your Roofing and Decking needs.
Follow the link to begin the conversation.

REQUEST QUOTE
CADdetails.com is a great resource for JRS design files configured for different CAD programs.  If you have a project requiring Corrosion Resistant Architectural Metals, specifying James River Steel roofing siding and decking is one of the easiest things you can do. It’s free, it’s very comprehensive, and they don’t spam.