Type B Cellular Deck
Type B Cellular Deck is mainly used in exposed ceiling areas where a flat bottom deck is wanted for aesthetic purposes. This is available in stainless steel and galvanized steel. Acoustical cellular deck is also available.
Type B Cellular Deck Properties
Section Properties (Fy=33 ksi)
| Gage Top/Bot | Weight (psf) Galv | Ip(In4) | In(In4) | Sp(In3) | Sn(In3) |
| 20/20 | 3.53 | 0.378 | 0.455 | 0.358 | 0.399 |
| 20/18 | 4.02 | 0.417 | 0.504 | 0.317 | 0.481 |
| 18/20 | 4.48 | 0.504 | 0.551 | 0.47 | 0.462 |
| 18/18 | 5.11 | 0.558 | 0.611 | 0.491 | 0.596 |
| 18/16 | 5.58 | 0.608 | 0.668 | 0.512 | 0.637 |
| 16/18 | 5.58 | 0.701 | 0.717 | 0.664 | 0.693 |
| 16/16 | 6.3 | 0.765 | 0.784 | 0.689 | 0.782 |
AVAILABLE Type B Cellular Deck
| Gage | Span Cond | Uniform Total Load in Pounds Per Square Foot (Dead and Live) | |||||||||||
| 6’-0” | 6’-6” | 7’-0” | 7’-6” | 8’-0” | 8’-6” | 9’-0” | 9’-6” | 10’-0” | 10’-6” | ||||
| 20/20 | One | 125 | 100 | 82 | 69 | 58 | 50 | 44 | 42 | 37 | 34 | ||
| 20/18 | 116 | 99 | 85 | 74 | 63 | 55 | 48 | 42 | 37 | 34 | |||
| 18/20 | 163 | 131 | 106 | 88 | 75 | 64 | 55 | 49 | 43 | 39 | |||
| 18/18 | 180 | 143 | 117 | 97 | 82 | 70 | 60 | 53 | 47 | 42 | |||
| 18/16 | 187 | 155 | 126 | 105 | 88 | 75 | 65 | 57 | 50 | 44 | |||
| 16/18 | 223 | 178 | 144 | 129 | 100 | 85 | 73 | 64 | 56 | 50 | |||
| 16/16 | 243 | 193 | 156 | 129 | 108 | 92 | 79 | 69 | 60 | 53 | |||
| 20/20 | Two | 146 | 124 | 107 | 93 | 82 | 73 | 65 | 58 | 53 | 48 | ||
| 20/18 | 176 | 150 | 129 | 113 | 99 | 88 | 78 | 70 | 63 | 57 | |||
| 18/20 | 169 | 144 | 124 | 108 | 95 | 84 | 75 | 67 | 61 | 55 | |||
| 18/18 | 218 | 186 | 160 | 140 | 123 | 109 | 97 | 87 | 79 | 71 | |||
| 18/16 | 233 | 199 | 171 | 149 | 131 | 116 | 104 | 93 | 84 | 76 | |||
| 16/18 | 254 | 216 | 186 | 162 | 143 | 126 | 113 | 101 | 91 | 83 | |||
| 16/16 | 286 | 244 | 210 | 183 | 161 | 143 | 127 | 114 | 103 | 93 | |||
| 20/20 | Three or More | 183 | 156 | 134 | 117 | 101 | 86 | 74 | 65 | 57 | 50 | ||
| 20/18 | 220 | 187 | 160 | 132 | 111 | 94 | 81 | 70 | 62 | 55 | |||
| 18/20 | 211 | 180 | 155 | 135 | 119 | 105 | 94 | 83 | 72 | 64 | |||
| 18/18 | 273 | 232 | 200 | 174 | 145 | 122 | 105 | 91 | 79 | 70 | |||
| 18/16 | 291 | 248 | 214 | 186 | 157 | 132 | 113 | 98 | 85 | 75 | |||
| 16/18 | 317 | 270 | 233 | 203 | 178 | 151 | 129 | 111 | 97 | 85 | |||
| 16/16 | 358 | 305 | 263 | 229 | 195 | 164 | 140 | 120 | 105 | 92 | |||
|